Memosens COS81E數(shù)字式熒光法溶解氧傳感器,采用Memosens 2.0技術(shù),專為衛(wèi)生型應(yīng)用場(chǎng)合設(shè)計(jì)。?該傳感器遵循EHEDG和ASME BPE標(biāo)準(zhǔn),符合美國(guó)藥典USP Cl. VI、FDA、GMP和GLP規(guī)范,適用于發(fā)酵工藝、飲用水生產(chǎn)等對(duì)無(wú)菌衛(wèi)生要求嚴(yán)格的領(lǐng)域。?其優(yōu)勢(shì)包括通過(guò)防爆認(rèn)證(如ATEX和IECEx),可在粉塵防爆區(qū)域和惰性保護(hù)防氧化過(guò)程中使用。?COS81E支持?jǐn)U展數(shù)據(jù)存儲(chǔ),便于趨勢(shì)識(shí)別和預(yù)維護(hù),是工業(yè)物聯(lián)網(wǎng)(IIoT)應(yīng)用的基礎(chǔ)。?
熒光法數(shù)字傳感器COS81E采用內(nèi)置參比LED光源,對(duì)測(cè)量光源老化進(jìn)行補(bǔ)償,即使經(jīng)過(guò)CIP/SIP和高壓滅菌,也能保持測(cè)量精度。?維護(hù)方面,電解液或傳感器膜的更換只需更換傳感器帽并執(zhí)行標(biāo)定,操作便捷。?傳感器可安裝于工藝過(guò)程和發(fā)酵罐中,支持實(shí)驗(yàn)室預(yù)標(biāo)定,即插即用,無(wú)需極化時(shí)間。?
COS81E通過(guò)防爆認(rèn)證,可以在粉塵防爆區(qū)域中測(cè)量,特別適合惰性保護(hù)防氧化過(guò)程。
熒光法數(shù)字傳感器COS81E優(yōu)勢(shì)
? Memosens COS81E遵循EHEDG和ASME BPE標(biāo)準(zhǔn)設(shè)計(jì)。消除了交叉污染風(fēng)險(xiǎn),符合美國(guó)藥典USP Cl. VI、FDA認(rèn)證、GMP和GLP規(guī)范的要求。
? 長(zhǎng)正常工作時(shí)間:允許實(shí)驗(yàn)室預(yù)標(biāo)定傳感器,即插即用,在線快速更換傳感器。無(wú)需極化時(shí)間,安裝后立即投用。
? 測(cè)量結(jié)果可靠:內(nèi)置參比LED光源,對(duì)測(cè)量LED光源的老化進(jìn)行補(bǔ)償。即使經(jīng)過(guò)CIP/SIP和高壓滅菌工藝,測(cè)量值仍然精準(zhǔn)。
? 低維護(hù)工作量:Memosens COS81E的電解液或敏感傳感器膜的更換十分便捷。只需更換傳感器帽,隨后執(zhí)行傳感器標(biāo)定即可。
? 傳感器可以安裝在工藝過(guò)程和發(fā)酵罐中使用。從首次實(shí)驗(yàn)室試驗(yàn)到批量生產(chǎn)和實(shí)驗(yàn)室應(yīng)用,結(jié)果始終穩(wěn)定一致。
? 傳感器通過(guò)防爆認(rèn)證,可以在粉塵防爆區(qū)域中測(cè)量,特別適合惰性保護(hù)防氧化過(guò)程。
? 支持IIoT工業(yè)物聯(lián)網(wǎng):Memosens 2.0支持?jǐn)U展數(shù)據(jù)存儲(chǔ),保存標(biāo)定和過(guò)程參數(shù),更好地進(jìn)行趨勢(shì)識(shí)別,是實(shí)施預(yù)維護(hù)和推進(jìn)IIoT技術(shù)的基礎(chǔ)。
熒光法數(shù)字傳感器COS81E技術(shù)參數(shù)
測(cè)量原理Optical oxygen measurement
應(yīng)用
? Oxygen control in fermenters, e.g. in the pharmaceutical or
biotechnology sectors
? Monitoring of explosive atmospheres with an oxygen concentration of
≥ 2% Vol
? Quality control in the food industry
安裝
Standard process connection Pg 13.5
Installation in standard pH assemblies possible
特點(diǎn)
Hygienic, optical sensor for stable oxygen measurement over multiple
sterilization cycles
測(cè)量范圍
0.004 to 30 mg/l
0.05 to 330 %SAT
0.1 to 700 hPa
測(cè)量原理Principle of luminescence quenching
設(shè)計(jì)Optical system, stainless steel
材質(zhì)
Sensor shaft: Stainless steel 1.4435 (AISI 316L)
Process seal: FKM (USP<87>, <88> Class VI and FDA)
Process seal for Ex versions: FKM (not FDA-compliant)
Seals/O-rings: EPDM, FFKM (USP<87>, <88> Class VI and
FDA)
Spot cap: Stainless steel 1.4435 (AISI 316L), titanium or hastelloy
Spot layer: Silicone (USP<87>, <88> Class VI and FDA)
外形尺寸
Diameter: 12 mm (0.47 inch)
Shaft length: 120, 160, 220, 320 and 420 mm
(4.7 , 6.3 , 8.7 , 12.6 and 16.5 inch)
過(guò)程溫度
0 to 60/80 °C (C-shape/U-shape)
32 to 140/175 °F (C-shape/U-shape)
Sterilization: max. 140 °C at 6 bar for max. 45 min
(Max. 284 °F at 87 psi for max. 45 min)
過(guò)程壓力
0.02 to 13 bar abs
(0 to 190 psi)
溫度傳感器Pt1000
防爆認(rèn)證
With ATEX, IECEx, NEPSI, Japan and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2 and furthermore Zone 20,
Zone 21 and Zone 22 in dust hazardous areas.
With CSA C/US approval for use in
hazardous areas Class I Division 1 and furthermore Class II Division 1 in
dust hazardous areas.
連接Inductive, digital connection head with Memosens 2.0 technology
防護(hù)等級(jí)IP68、IP69
其他證書(shū):
Inspection certificate 3.1, EN10204
Surface roughness test ISO4287/Ra (≤ 0,38 μm)
Conformity to cGMP derived requirements
ASME BPE
US Food Contact Materials FDA CFR 21
EU Food Contact Materials (EG) 1935/2004
CN Food Contact Materials GB 4806
EHEDG EL Class I
應(yīng)用領(lǐng)域
Memosens COS81E可以在有嚴(yán)格無(wú)菌衛(wèi)生要求的場(chǎng)合中測(cè)量,例如:
發(fā)酵工藝
飲用水生產(chǎn)
惰性保護(hù)防氧化過(guò)程
Memosens COS81E溶解氧傳感器通過(guò)國(guó)際防爆認(rèn)證,例如ATEX和IECEx,可以在危險(xiǎn)區(qū)中使用